Password Setups 326
Speed Limit Input The Speed Limit Input is used to limit the machine speed for safety
during machine testing and maintenance. When active, motion will be
limited to the user defined Limited Machine Speed selected in the
password protected Speeds screen
Tilt +/– Overtravel Switch This input indicates that the machine has traveled into its full positive
travel in the Tilt axis. If the hardware overtravels are enabled and this
input is activated, the control will stop all motion, generate a fault
message and only allow manual motion in the Tilt axis opposite
direction. The Tilt Overtravel Input is also used for Homing of the Tilt
Axis.
Tilt +/– Tilt +/- inputs are used for manual jog commands for the Tilt Axis.
Tilt Home Feature This feature uses the Tilt Overtravel Switch input to indicate that the
machine has traveled to its Tilt axis home position. When a Homing
function is performed, the Tilt axis moves in the specified home
direction at the Fast Home Speed until the input is activated. The Tilt
axis then decelerates to a stop and moves in the opposite direction at
the Slow Home Speed until the switch is deactivated. Also see Tilt
Overtravel Switch
Rotate +/– Rotate +/- inputs are used for manual jog commands for the Rotate
Axis.
Rotate Home Switch This input indicates that the machine has traveled to its Rotate axis
home position. When a Homing function is performed, the Rotate axis
moves in the specified home direction at the Fast Home Speed until the
input is activated. The Rotate axis then decelerates to a stop, moves in
the opposite direction at the Slow Home Speed until the switch is
deactivated.
Pierce Complete The Pierce Complete input is used for the Laser Cut Process and is
used to confirm that the pierce is complete.
Gas Control Read Comp. The Gas Control Read Complete input is used as part of the HD3070
®
Automatic Gas Console communications to confirm communications is
complete.
Gas Control Error The Gas Control Error input is used as part of the HD3070
®
Automatic
Gas Console communications to notify of an error from the Auto Gas
Console.
Enable Oxy Fuel 1-12 These inputs are used for tracking of consumable data for the specified
Oxy Torch. This input is now supported by the Station Select input.
Enable Plasma 1-8 These inputs are used for tracking of consumable data for the specified
Plasma Torch. This input is now supported by the Station Select input.
Arc Error Counter 1-8 Used as part of the tracking for consumable data, this input triggers a
counter on the Change Consumable Screen. A Plasma Enable Input
must be mapped to have this enable available for use.
Test Lifter This Input is used to perform a test IHS function with a Sensor™ THC.