7.42. OutFade Command
This page describes the syntax and how to use the OutFade command.
To go to the OutFade command it is necessary to press another function key before, e.g. Store and press Time
twice (= OutFade).
Description
With the OutFade command, you can indicate out fade times
for a new cue with out fade time
in a existing cue
Indicate out fade times for getting smaller dimmer values.
Syntax
1. Store a new cue 1 with an out fade time of 4 seconds.
Store Cue 1 OutFade 4
2. Assign a out fade time of 5 seconds to the existing cue 3 on executor 1.
Assign OutFade 5 Cue 3 Executor 1
Example 1
Let´s assume, you will store a new cue on the main executor with an out fade time of 4 seconds.
Press Store 1 (= Cue 1) two times Time (= OutFade) 4 Please .
Cue 1 is stored with an out fade time of 4 seconds.
Double check the cue timing in the Cues View.
Example 2
Let´s assume, you will assign an out fade time of 5 seconds to the existing cue 3 stored on executor 1.
Press + Label (=Assign) two times Time (= OutFade) 5 Cue 3 Exec 1 Please .
Cue 3 on executor 1 has now an out fade time of 5 seconds.
Related Links
Time Key
Cues View
Store Command
386

Table of Contents

Other manuals for MA dot2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MA dot2 and is the answer not in the manual?

MA dot2 Specifications

General IconGeneral
BrandMA Lighting
Operating Systemdot2 OS
CategoryLighting Console
ProtocolsArt-Net, sACN
DMX Channels4096
Ethernet Ports2
Power Supply100-240V, 50/60Hz