6.50. Select Button for Remote Inputs Configuration
To open the Select Type Window, select the respective cell and press and hold the cell of the column Button, or
press the scroll encoder, in the Remote Inputs Configuration Window.
If the selected type in the remote inputs configuration is Exec, you have to selected the kind of executor, the button.
The number of available options depends on the entered executor number in the executor column, e.g. if the
executor number is 101, the button can only be a button 1.
Button 2:
Select button 2, if the executor is a flash key .
Fader:
Select fader, if the velocity shall control the fader (MIDI or DMX values).
Button 1:
Select button 1, if the executor is a go key .
To leave the Select Button Window, tap in the title bar. You are back in the Remote Inputs Configuration
Window.
Encoder Bar Functions
Scroll:
To scroll left or right, press and turn the encoder left or right.
To apply a selection, press the encoder.
6.51. Select DMX Address... Window
The Select DMX Address... Window is located at the Setup, tap Patch & Fixture Schedule.
1. For existing fixtures:
press and hold in the column Patch the cell from the fixture you want patch.
2. For new fixtures: