EasyManua.ls Logo

MacDon FlexDraper FD140 - Checking Reel Height Sensor Voltages (Case IH)

MacDon FlexDraper FD140
628 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
214683 164 Revision A
Checking Reel Height Sensor Voltages (Case IH)
NOTE:
Changes may have been made to the combine controls or display since this document was published. Refer to the
combine operators manual for updates.
1023899
A
Figure 3.243: Case IH Combine Display
1. On the main page of the combine display, select
DIAGNOSTICS (A). The DIAGNOSTICS page opens.
10239001023900
A
B
C
Figure 3.244: Case IH Combine Display
2. Select SETTINGS tab (A). The SETTINGS page opens.
3. From the GROUP menu, select HEADER (B).
4. From the PARAMETER menu, select REEL VERTICAL
POSITION (C).
1023897
A
B
C
Figure 3.245: Case IH Combine Display
5. Select GRAPH tab (A). The REEL VERTICAL
POSITION graph displays.
6. Lower the reel to view the high voltage (B). The voltage
should be 4.14.5 V.
7. Raise the reel to view the low voltage (C). The voltage
should be 0.50.9 V.
8. If either voltage is out of range, refer to Checking and
Adjusting Reel Height Sensor, page 96.