Figure 3.257: Challenger Combine Display
4. Press the HEADER button (A). The HEADER
CALIBRATION screen displays a warning.
Figure 3.258: Challenger Combine Display
5. Read the warning message, and then press the green
check mark button.
Figure 3.259: Challenger Combine Display
6. Follow the on-screen prompts to complete calibration.
NOTE:
The calibration procedure can be canceled at any time
by pressing the cancel button in the bottom right corner
of the screen. While the header calibration is running,
the calibration can also be canceled by using the UP,
DOWN, TILT RIGHT, or TILT LEFT buttons on the
control handle.
NOTE:
If the combine does not have HEADER TILT installed or
if it is inoperable, you may receive warnings during
calibration. Press the green check mark if these
warnings appear. This will not affect the AHHC
calibration.
NOTE:
If float was set heavier to complete the AHHC
calibration procedure, adjust to recommended
operating float after the calibration is complete.