214683 354 Revision A
Figure 4.99: Multicoupler Storage
10. Position the multicoupler (A) on the float module
receptacle and lower the handle (B) to lock the
multicoupler.
Figure 4.100: Feeder House Locks
11. Push the handle (A) on the combine towards the feeder
house to disengage the feeder house pin (B) from the
float module.
Figure 4.101: Header/Feeder House
12. Lower the feeder house until the saddle (A) disengages
and clears the float module support (B).
13. Back the combine away slowly from the float module.
HEADER ATTACHMENT/DETACHMENT