Station Message Detail Recording
330 Features DSX Software Manual
Conditions
None
Default Setting
SMDR output disabled.
72 Space
73 T
74 Space
3 1-3 - characters
4 + character
5-7 - characters
8 + character
9-40 - characters
41 + character
42-51 - characters
52 + character
53-61 - characters
62 + character
63-70 - characters
71 + character
72-74 - characters
Call Record
1 1-3 Extension number
4 | character
5-7 Line number (2 digits, right justied, preceded by
one space)
8 | character
9-40 Number dialed (up to 20 characters, right justied,
preceded by spaces)
41 | character
42-51 Account Code (right justied, preceded by spaces)
52 | character
53-61 Start time of call (hh:mm:ssA or P)
62 | character
63-70 Duration of call (hh:mm:ss)
71 | character
72-74 Type of call