16xx-Timers
161x-COI (Analog Line) Timers
1612-Outgoing
686 System Options: 1001-1702 DSX Software Manual
Options
100-9999 mS
Default
800 mS
1612-04: PBX/Centrex Flash Timer
(Flash 1 Time)
Use this timer to set the Flash interval. When a user ashes a line (manually or in a Speed Dial number), the
system opens the line circuit for this interval. For accurate ash function, be sure to set this interval for com-
patibility with the connected telco or PBX/Centrex. If you set this interval too short, the telco may not
always register the ash. If too long, inadvertent disconnects may occur.
Features
Flash (page 177)
Speed Dial (page 315)
IntraMail Features
Centrex Transfer (page 460)
Options
16-4080 mS
Default
800 mS
1612-05: Flash Disconnect Timer
(Flash 2 Time)
This option is currently not implemented.
Features
None
IntraMail Features
None
Options
16-4080 mS
Default
2496 mS
1612-06: Ground Start Timer
(Ground Time)
Before the system can start a ground start line, the telco’s tip ground must be present for longer than this
interval. Set this interval for compatibility with the connected telco or PBX/Centrex. If you set this interval
too short, the system may inadvertently start a line it should not set up. If too long, the system may not start
lines that are functioning normally.
Features
None
IntraMail Features
None
Options
16-4080 mS
Default
800 mS