EasyManua.ls Logo

NEC DSX - 1605-Control Timers; 1605-01: Page Duration Timer; 1605-02: Meet Me Conference Join Timer; 1605-03: Door Relay Unlock Timer

NEC DSX
984 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16xx-Timers
160x-Feature Timers
1605-Control Timers
680 ◆ System Options: 1001-1702 DSX Software Manual
1605-Control Timers
Description
Use this program to adjust timers that affect various system features.
Options
1605-01: Page Duration Timer
(Page Duration)
Use this option to set the maximum length of Page announcements.
F
eatures
• Paging (page 259)
IntraMail Features
• None
Options
• 1-9999 seconds
• 0 for disabled
Default
• 30 seconds
1605-02: Meet Me Conference Join Timer
(Meetme Conf)
When a user initiates a Meet-Me Conference, use this option to set how long the system waits for the paged
party to join the call.
Features
• Meet-Me Conference (page 236)
IntraMail Features
• None
Options
• 1-9999 seconds
•
0 for disabled
Default
• 30 seconds
1605-03: Door Relay Unlock Timer
(Door Relay)
This timer sets the interval that the system or PGDAD Module relay remains closed after a keyset user acti-
vates (closes) the relay. After this interval, the relay automatically returns to its open (idle) state.
Features
• Door Box (page 147)
IntraMail Features
• None
Options
• 1-9999 seconds
• 0 for disabled
Default
• 30 seconds

Table of Contents