31xx-Configuration
310x-Setup
3101-Type
DSX Software Manual Line Options: 3101-3714 809
Line
3101-3715
Lines: 3101-3715
31xx-Conguration
310x-Setup3101-Type
Description
Use this program to set the line circuit type, name, PBX option, and E1 signaling (for Latin America instal-
lations only).
If programming multiple lines, you may nd 9022-Line Copy (page 923) a handy time-saving tool.
Options
3101-01: Line Type
(Type)
Use this option to set the line’s circuit type for compatibility with the connected telco or PBX.
Features
Central Ofce Calls, Answering (page 74)
Central Ofce Calls, Placing (page 78)
Direct Inward Dialing (page 99)
Direct Inward Line (page 109)
Pulse to Tone Conversion (page 285)
T1 Lines (page 338)
Tie Lines (page 344)
IntraMail Features
None
Options
00 for uninstalled
01 for Loop start
02 for Ground Start
1
03 for DID Wink Start
1
04 for DID Immediate Start
1
05 for E&M Wink Start
1
06 for E&M Immediate Start
1
1
Requires T1 PCB.
Default
•51