NEC DSX - Lines: 3101-3715; 31 Xx-Configuration; 310 X-Setup; 3101-01: Line Type

NEC DSX
984 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
31xx-Configuration
310x-Setup
3101-Type
DSX Software Manual Line Options: 3101-3714 ◆ 809
Line
3101-3715
Lines: 3101-3715
31xx-Configuration
310x-Setup3101-Type
Description
Use this program to set the line circuit type, name, PBX option, and E1 signaling (for Latin America instal-
lations only).
If programming multiple lines, you may find 9022-Line Copy (page 923) a handy time-saving tool.
Options
3101-01: Line Type
(Type)
Use this option to set the line’s circuit type for compatibility with the connected telco or PBX.
Features
• Central Office Calls, Answering (page 74)
• Central Office Calls, Placing (page 78)
• Direct Inward Dialing (page 99)
• Direct Inward Line (page 109)
• Pulse to Tone Conversion (page 285)
• T1 Lines (page 338)
• Tie Lines (page 344)
IntraMail Features
• None
Options
• 00 for uninstalled
• 01 for Loop start
• 02 for Ground Start
1
• 03 for DID Wink Start
1
• 04 for DID Immediate Start
1
• 05 for E&M Wink Start
1
• 06 for E&M Immediate Start
1
1
Requires T1 PCB.
Default
•51