31xx-Configuration
310x-Setup
3101-Type
DSX Software Manual Line Options: 3101-3714 809
Line
3101-3715
Lines: 3101-3715
31xx-Conguration
310x-Setup3101-Type
Description
Use this program to set the line circuit type, name, PBX option, and E1 signaling (for Latin America instal-
lations only).
If programming multiple lines, you may nd 9022-Line Copy (page 923) a handy time-saving tool.
Options
3101-01: Line Type
(Type)
Use this option to set the line’s circuit type for compatibility with the connected telco or PBX.
Features
Central Ofce Calls, Answering (page 74)
Central Ofce Calls, Placing (page 78)
Direct Inward Dialing (page 99)
Direct Inward Line (page 109)
Pulse to Tone Conversion (page 285)
T1 Lines (page 338)
Tie Lines (page 344)
IntraMail Features
None
Options
00 for uninstalled
01 for Loop start
02 for Ground Start
1
03 for DID Wink Start
1
04 for DID Immediate Start
1
05 for E&M Wink Start
1
06 for E&M Immediate Start
1
1
Requires T1 PCB.
Default
•51

Table of Contents

Other manuals for NEC DSX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC DSX and is the answer not in the manual?

NEC DSX Specifications

DSX-40

Stations and Lines IconStations and Lines
digital stations8
analog stations2
lines4
Voice Mail IconVoice Mail
voice mail ports4 or 8
storage hours8 or 16
mailboxes66

DSX-80

Stations and Lines IconStations and Lines
digital stations32
analog stations32
lines64
Voice Mail IconVoice Mail
voice mail ports4 or 8
storage hours8 or 16
mailboxes160

DSX-160

Stations and Lines IconStations and Lines
digital stations96
analog stations96
lines64
Slots IconSlots
slots8
Voice Mail IconVoice Mail
voice mail ports4 or 8
storage hours8 or 16
mailboxes160