EasyManua.ls Logo

NEC DSX - 1612-07: Shunt Pause Timer

NEC DSX
984 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16xx-Timers
161x-COI (Analog Line) Timers
1612-Outgoing
DSX Software Manual System Options: 1001-1702 687
System
1001-1702
1612-07: Shunt Pause Timer
(Shunt Pause)
Use this option to set the Shunt Pause Timer (Dial Pulse Mute Timer) for the ATRU PCB. While dial pulsing
or doing a Flash, the ATRU PCB switches a low resistance shunt across tip and ring to maintain the correct
impedance on the line. When dialing or ashing is complete, the ATRU PCB waits this interval before
releasing the shunt.
This option does not apply to the COIU PCB.
Features
None
IntraMail Features
None
Options
4-1020 mS
Default
8 mS