Elite IPK Document Revison 1
Programming Manual 2 - 423
___________________________________________________________________________________
___________________________________________________________________________________
3-40 Automatic Release Signal Detection
Selection
General Description
Use this Memory Block to specify the signal detection time for release of a CO/PBX
line after a disconnect signal is received from the distant Central Office or PBX.
Display
Settings
Page 1
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7
LK 8
The shaded
selection is the
default. Times
are in
milliseconds.
0 50 100 150 200 250 300
350
Page 2
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8
400 450 500 550 600 650 700
∞
(NO limit)
Programming Procedures
1 Go off-line.
2 Press LK3 +
G
+
DK
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change signal release time for CO/PBX No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or CO/PBX No.
– OR –
D
to go to the next assigned CO/PBX No.
C
to go to the next page.
A
to go to the previous page.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.