A - 2 Function Time Chart
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1 Elite IPK
CO/PBX Incoming
Ringing Alarm Time
Selection
1-1-06 The time after an incoming
CO/PBX call is detected before
the ringing tone changes to a
different ringing tone level
when the call is not answered.
10s
∞∞
Tie Line Delay
Ringing Time
Selection
1-1-07 The time between when a
telephone rings (accessed by a
ringing call in the Tie/DID line)
and calls can start ringing at
other assigned stations when it
is not answered.
10s
∞∞
Station Transfer/
Camp-On Recall
Time Selection
1-1-12 The time before a ring
transferred call recalls to the
station that transferred the call.
25s 45s
Trunk Queuing
Timeout Selection
1-1-37 The time a station with Trunk
Queue set rings before the
queue is automatically
canceled.
10s 10s 60s
CO/PBX Prepause
Time Selection
1-1-57 The time before dialed digits
are sent over a CO/PBX line
after the line is seized.
NON 1s 13s
Hold Recall Time
Selection
(Exclusive)
1-1-63 The time (minutes) for
Exclusive Hold Recall. No limit
disables this feature.
0.5 1.0
Attendant Add-On
Console Transfer/
Camp-On Recall
Time Selection
1-1-64 The time (minutes) before a
ring transfer or a station camp-
on from a station with an
Attendant add on console
recalls to the originating station
if unanswered.
0.5 1.0 10.0
First Delay
Announcement
Start Time Selection
1-1-71 The time (seconds) between
receiving an incoming CO call
and sending the First Delay
Announcement to the caller.
00 20 60
First to Second
Delay
Announcement
Interval Time
Selection
1-1-73 The time (seconds) between
the end of the First Delay
Announcement and the
beginning of the second
Second Delay Announcement.
00 20
Table A-1 Function Time Chart (Continued)
Time
Memory
Block
Definition
Value