C-60 Parameter Reference
AC30 series Variable Speed Drive
Parameter Name
No.
Path
Default
Range
Units
Writable
14:87.0 A 400 V
15:105 A 400 V
16:145 A 400 V
17:180 A 400 V
18:205 A 400 V
19:260 A 400 V
20:45.0 A 400 V
21:60.0 A 400 V
22:73.0 A 400 V
23:315 A 400 V
24:380 A 400 V
25:440 A 400 V
26:530 A 400 V
27:590 A 400 V
28:650 A 400 V
29:700 A 400 V
30:790 A 400 V
The rating of the power stack that the Control Module is fitted to. When the Control Module not attached to a stack this parameter is not
visible and is ignored.
The Power Stack names ending in “R1” are for the initial release of Frame G stacks with ventilation holes in the casing. Later revisions
of the Frame G stacks have no ventilation holes but have an internal cooling fan.
Attached to Stack
0695
Parameters::Device Manager::Drive info
NEVER
A Boolean parameter that indicates that the Control Module is attached to a power stack. When the Control Module is not attached to a
stack but is powered using the auxiliary 24v input this parameter will indicate FALSE.
Stack Pcode
1109
Parameters::Device Manager::Drive info
NEVER
The product code string that may be used to order an equivalent Power Stack.
Stack Serial No
1258
Parameters::Device Manager::Drive info
NEVER
The serial number of the Power Control Card, (part of the Power Stack assembly).
Control Module Pcode
1116
Parameters::Device Manager::Drive info
NEVER

Table of Contents

Other manuals for Parker AC30 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC30 series and is the answer not in the manual?

Parker AC30 series Specifications

General IconGeneral
Control ModesClosed-loop vector
FeedbackEncoder
Operating Temperature0 to 40°C (32 to 104°F) standard, -20 to 50°C (-4 to 122°F) with derating
ProtectionOvercurrent, Overvoltage, Undervoltage