SOURce:POWer:CORRection:PSELect <CalPower>
Defines how to define the source power the R&S ZNL/ZNLE uses to perform the first
calibration sweep of the source power calibration ("Reference Receiver Cal Power").
Parameters:
<CalPower> CPOWer | PPOWer
CPOWer
Calculated port power result
PPOWer
Predefined port power value, see SOURce:POWer:
CORRection:PPOWer
*RST: CPOWer
Example: See SOURce<Ch>:POWer:CORRection[:ACQuire].
Manual operation: See "Reference Receiver Cal Power" on page 513
SOURce<Ch>:POWer<PhyPt>:CORRection:STATe <Boolean>
Enables or disables the source power calibration for channel <Ch> and for port number
<PhyPt>. The setting command is disabled unless a source power calibration for the
analyzer port has been performed (SOURce<Ch>:POWer:CORRection[:ACQuire]).
The query always returns a result.
Suffix:
<Ch>
.
Calibrated channel number
<PhyPt> Calibrated port number
Parameters:
<Boolean> Enables (ON) or disables (OFF) the source power calibration for
port number <PhyPt>.
*RST: OFF
Example: See SOURce<Ch>:POWer:CORRection[:ACQuire].
Manual operation: See "Port Overview" on page 522
SOURce:POWer... (other)
The SOURce:POWer... commands define the power of the internal signal source.
SOURce<Ch>:POWer<PhyPt>:CORRection:LEVel:OFFSet............................................... 992
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate][:AMPLitude]........................................ 992
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:OFFSet.............................................. 993
SOURce<Ch>:POWer<PhyPt>[:LEVel][:IMMediate]:SLOPe............................................... 994
SOURce:POWer:REDuce:SDELay.................................................................................. 994
SOURce<Ch>:POWer<PhyPt>:REDuce[:STATe]...............................................................994
SOURce<Ch>:POWer<PhyPt>:STATe..............................................................................995
SOURce<Ch>:POWer<PhyPt>:STARt............................................................................. 995
VNA command reference

Table of Contents

Other manuals for R&S ZNL Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNL Series and is the answer not in the manual?

R&S ZNL Series Specifications

General IconGeneral
BrandR&S
ModelZNL Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals