R&S
®
ZVA / R&S
®
ZVB / R&S
®
ZVT Command Reference
SCPI Command Reference
Operating Manual 1145.1084.12 – 30 877
to the default source power value.
See also example for SENSe<Ch>:]CORRection:POWer<port_no>:ACQuire.
[SENSe<Ch>:]CORRection:PSTate?
Returns the power calibration state label of the active trace in channel <Ch>.
Channel number used to identify the active trace.
String variable containing the power calibration state label in the trace list ('PCal',
'PCai', 'PCa?', 'PCao', 'PCax', 'PCal Off'; see Power Calibration State Labels).
'' (empty string, is returned e.g. if no power calibration is available for channel
<Ch>)
Device-specific, query only
See SOURce<Ch>:POWer:CORRection[:ACQuire]
[SENSe<Ch>:]CORRection:SSTate?
Returns the system error correction state label of the active trace in channel <Ch>.
Channel number. used to identify the active trace.
String variable containing the calibration state label in the trace list ('Cal', 'Cai',
'Ca?', 'Cav', 'Cal Off'; see System Error Correction State Labels).
'' (empty string, is returned e.g. if no system error correction is available for
channel <Ch>)
Device-specific, query only
See [SENSe<Ch>:]CORRection:DATE?
[SENSe<Ch>:]CORRection[:STATe] <Boolean>
Enables or disables the system error correction for channel <Ch>.
Calibrated channel number
Enables (ON) or disables (OFF) the correction.
Confirmed, command or query
*RST; :CORR?
Reset the instrument and query whether channel 1 is system error corrected.