10
10-22
MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
32180 Group User’s Manual (Rev.1.0)
TIN5–8 Input Processing Control Register (TIN58CR) <Address: H’0080 0214>
b01234567891011121314b15
TIN8S TIN7S TIN6S TIN5S
00
0
00
000
<After reset: H’0000>
b Bit Name Function R W
0 No function assigned. Fix to "0". 00
1–3 TIN8S 000: Disable input R W
TIN8 input processing select bit 001: Rising edge
010: Falling edge
011: Both edges
100: Low level
101: Low level
110: High level
111: High level
4 No function assigned. Fix to "0". 00
5–7 TIN7S 000: Disable input R W
TIN7 input processing select bit 001: Rising edge
010: Falling edge
011: Both edges
100: Low level
101: Low level
110: High level
111: High level
8 No function assigned. Fix to "0". 00
9–11 TIN6S 000: Disable input R W
TIN6 input processing select bit 001: Rising edge
010: Falling edge
011: Both edges
100: Low level
101: Low level
110: High level
111: High level
12 No function assigned. Fix to "0". 00
13–15 TIN5S 000: Disable input R W
TIN5 input processing select bit 001: Rising edge
010: Falling edge
011: Both edges
100: Low level
101: Low level
110: High level
111: High level
Note: • This register must always be accessed in halfwords.