10.4 TIO (Input/Output-Related 16-Bit Timer)
MULTIJUNCTION TIMERS
32180 Group Users Manual (Rev.1.0)
TIO5 Control Register (TIO5CR) <Address: H0080 034B>
9 1011121314b15b8
TIO5MTIO5CKS TIO5ENS
00000000
<After reset: H00>
b Bit Name Function R W
8–10 TIO5CKS 000: External input TCLK1 R W
TIO5 clock source select bit 001: ditto
010: ditto
011: ditto
100: Clock bus 0
101: Clock bus 1
110: Clock bus 2
111: Clock bus 3
11, 12 TIO5ENS 00: No selection R W
TIO5 enable/measure input source select bit 01: ditto
10: External input TIN7
11: Input event bus 3
1315 TIO5M 000: Single-shot output mode R W
TIO5 operation mode select bit 001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: ditto
Note: Operation mode can only be set or changed while the counter is inactive.