Remote Control
R&S
®
FSVA/FSV
947Operating Manual 1176.7510.02 ─ 09
MMEMory:SELect[:ITEM]:HWSettings <State>
This command includes the hardware settings in the settings file to be stored/loaded.
The hardware settings include:
●
current configuration of general device parameters (general setup)
●
current setting of the measurement hardware including markers
●
activated limit lines:
A settings file may include 8 limit lines at maximum. This number includes the activated
limit lines and, if available, the de-activated limit lines last used.
Therefore the combination of the non-activated restored limit lines depends on the
sequence of use with the MMEMory:LOAD:STATe on page 942 command.
●
user-defined color setting
●
configuration for the hardcopy output
Parameters:
<State> ON | OFF
*RST: ON
Example:
MMEM:SEL:HWS ON
Manual operation: See "Select Items" on page 198
MMEMory:SELect[:ITEM]:LINes:ALL <State>
This command includes all limit lines (activated and de-activated) in the settings file to
be stored/loaded.
Parameters:
<State> ON | OFF
*RST: OFF
Example:
MMEM:SEL:LIN:ALL ON
Manual operation: See "Select Items" on page 198
MMEMory:SELect[:ITEM]:NONE
This command excludes all items from the settings file to be stored/loaded.
Example:
MMEM:SEL:NONE
Usage: Event
Manual operation: See "Disable all Items" on page 199
MMEMory:SELect[:ITEM]:SGRam <boolean>
This command adds the spectrogram data to the list of data subsets of a save/recall
device setting.
Remote Control – Commands