Remote control commands
R&S
®
SMB100B
560User Manual 1178.3711.02 ─ 08
<Freq> xxx.x
Sets the alternative frequencies as ASCII coded decimal num-
bers.
If list <z> is not available, the response is ().
Note: For each Enhanced Other Network (EON), a maximum of
five type B alternative frequency lists can be created. Each list
contains a maximum of five frequencies, where <Freq#1> is
Tuned Frequency (TF) and <Freq#2..5> are the Mapped Fre-
quencies (MF). A minimum of two frequencies per EON is
required.
Range: 87.6 to 107.9
Setting parameters:
<A> N
New AF list
+
AF list to be added.
Query parameters:
<z> AF list to be read.
Range: 1 to 5
Example: See STEReo:DIRect.
STEReo:DIRect "EON-DEL=<PI>"
Enhanced Other Networks: Deletes the complete EON with selected <PI>.
Parameters:
<PI> Range: 0000 to FFFF (ASCII coded hexadecimal num-
bers)
Example:
STEReo:DIRect "EON-DEL=1000"
Deletes the EON with PI=1000.
Usage: Setting only
STEReo:DIRect "EON-PI=<PI>"
STEReo:DIRect? "EON-PI"
Enhanced Other Networks: Creates an EON or reads the list of the program identifica-
tion (PI) codes of all EONs created so far.
Note: A maximum of eight EONs can be created.
Parameters:
<PI> Note: Always set a four-digit value. Leading zeros, if any, must
also be specified.
Range: 0000 to FFFF (ASCII coded hexadecimal num-
bers)
Direct commands for the stereo/rds coder option R&S SMBB-B5