EasyManua.ls Logo

Rohde & Schwarz SMBV100A - 7.2 Common Commands; Cls; Common Commands; Ese

Rohde & Schwarz SMBV100A
911 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
505Operating Manual 1176.8016.02 ─ 17
7.2 Common Commands
Common commands are described in the IEEE 488.2 (IEC 625-2) standard. These
commands have the same effect and are employed in the same way on different devi-
ces. The headers of these commands consist of "*" followed by three letters. Many
common commands are related to the Status Reporting System.
Available common commands:
*CLS.............................................................................................................................505
*ESE.............................................................................................................................505
*ESR?...........................................................................................................................505
*IDN?............................................................................................................................506
*IST?............................................................................................................................ 506
*OPC............................................................................................................................506
*OPT?...........................................................................................................................506
*PRE............................................................................................................................ 507
*PSC............................................................................................................................ 507
*RCL.............................................................................................................................507
*RST.............................................................................................................................507
*SAV.............................................................................................................................508
*SRE............................................................................................................................ 508
*STB?...........................................................................................................................508
*TRG............................................................................................................................ 508
*TST?........................................................................................................................... 509
*WAI.............................................................................................................................509
*CLS
Clear status
Sets the status byte (STB), the standard event register (ESR) and the EVENt part of
the QUEStionable and the OPERation registers to zero. The command does not
alter the mask and transition parts of the registers. It clears the output buffer.
Usage:
Setting only
*ESE <Value>
Event status enable
Sets the event status enable register to the specified value. The query returns the con-
tents of the event status enable register in decimal form.
Parameters:
<Value> Range: 0 to 255
*ESR?
Event status read
Common Commands

Table of Contents

Other manuals for Rohde & Schwarz SMBV100A

Related product manuals