Parameters:
<Source> INTernal | NEXT
INTernal
Switch over to any segment is triggered manually by means of
the command BB:ARB:WSEG:NEXT:EXEC.
NEXT
The trigger event for switching to the next segment is input on
the NEXT connector.
*RST: INTernal
Example:
BB:ARB:WSEG:NEXT:SOUR INT
selects internal next segment source.
Manual operation: See "Next Segment Source" on page 399
[:SOURce<hw>]:BB:ARBitrary:WSEGment:SEQuence:APPend
<State>,
<Segment>, <Count>, <Next>
Appends a new segment to the selected sequencing play list.
Setting parameters:
<State> ON | OFF
activates/deactivates the appended segment
*RST: ON
<Segment> integer
indicates the number of the segment as in the multi segment
waveform file
Range: 0 to SegmentCount - 1
<Count> integer
defines how many times this segment is repeated
Range: 1 to 65535
<Next> NEXT | BLANk | ENDLess | SEG0 | SEG1 | ... | SEG31 |
0...maxSegment
determines the action after completing the current segment, like
for instance which segment is processed after the processing of
the current one is finished.
Example:
BB:ARB:WSEG:SEQ:SEL '/var/user/play_list_1’
selects the sequencing list play_list_1.wvs.
BB:ARB:WSEG:SEQ:APP ON,3,15,BLANK
appends the segment number 3 as a new segment to the
sequencing list; this segment is activated and will be repeated
15 times and followed by a blank segment.