Remote Control Commands
R&S
®
SMBV100A
512Operating Manual 1176.8016.02 ─ 17
then described in alphabetical order. Most tags are valid for all three file types. If a tag
is valid only for a single file type, e.g. only for a waveform, this fact is indicated in the
description.
{TYPE: magic, xxxxxxxx}................................................................................................ 512
{CLOCK: frequency}.......................................................................................................513
{COMMENT: string} .......................................................................................................513
{COPYRIGHT: string}..................................................................................................... 514
{DATA BITLENGTH: BitLength}.......................................................................................514
{DATA LIST-Length: #d0d1...dx...dN-1…}.........................................................................514
{DATE: yyyy-mm-dd;hh:mm:ss}....................................................................................... 515
{EMPTYTAG-Length: #EmptySequence}..........................................................................515
{CONTROL LENGTH: ControlLength}.............................................................................. 516
{LEVEL OFFS: RMSOffset_dB,PeakOffset_dB}................................................................ 517
{SAMPLES: Samples}.................................................................................................... 518
{[TRACE] LIST [#]: Pos0:State0; Pos1:State1; ...PosN-1:StateN-1}..................................... 518
{WAVEFORM-Length: #I0Q0I1Q1...IxQx...IN-1QN-1…}..................................................... 519
{MWV_SEGMENT_COUNT: NumOfSeg}......................................................................... 520
{MWV_SEGMENT_LENGTH: SamplesSeg0, SamplesSeg1, …, SamplesSegN-1}............... 521
{MWV_SEGMENT_START:
SampleStartOffsetSeg0, SampleStartOffsetSeg1, …, SampleStartOffsetSegN-1}.......521
{MWV_SEGMENT_CLOCK_MODE: Mode}...................................................................... 521
{MWV_SEGMENT_CLOCK: ClockSeg0, ClockSeg1, …, ClockSegN-1}...............................522
{MWV_SEGMENT_LEVEL_OFFS:
RMSOffs_dBSg0,PeakOffs_dBSg0, …, RMSOffs_dBSgN-1, PeakOffs_dBSgN-1}......523
{MWV_SEGMENT_FILES:
“FileNameSeg0.wv”, “FileNameSeg1.wv”, …, “FileNameSegN-1.wv”}........................523
{MWV_SEGMENTx_COMMENT: text}............................................................................. 523
{CONTROL LIST WIDTH4–Length: #m0m1…mx…mM-1}..................................................523
{TYPE: magic, xxxxxxxx}
(mandatory, must be the first tag in the file)
Identifies the file as a valid R&S SMBV file. It must be present and must be the first in
the waveform. If a file of the same name exists on the target medium, it is overwritten.
Setting parameters:
magic Designates the file type and has the following values:
SMU-WV
A valid R&S SMBV waveform.
SMU-MWV
A valid R&S SMBV multi-segment waveform.
SMU-DL
A valid R&S SMBV data list.
SMU-CL
A valid R&S SMBV control list.
Waveform and List Format