Remote Control Commands
R&S
®
SMBV100A
575Operating Manual 1176.8016.02 ─ 17
Setting parameters:
<Directory> string
String parameter to specify the directory to be deleted.
Example: See "Working with Files and Directories" on page 566.
Usage: Event
:MMEMory:STORe:STATe <savrcl_state_nr>, <file_name>
Stores the current instrument setting in the specified file.
The instrument setting must first be stored in an internal memory with the same num-
ber using the common command *SAV.
Setting parameters:
<savrcl_state_nr> Corresponds to the specific <number> defined with the *SAV
command, e.g. *SAV 4.
<file_name> String parameter to specify the file name with extension
*.savrcltxt.
Example: See "Storing and Loading Current Settings" on page 566.
Usage: Event
Manual operation: See " Save" on page 162
7.14 OUTPut Subsystem
The OUTPut system contains the commands which set the properties of the RF
OUTPUT connectors and USER connectors.
The properties of the LF output connector are set in the SOURce:LFOutput Subsystem
system.
:OUTPut<hw>:AFIXed:RANGe:LOWer?........................................................................... 575
:OUTPut<hw>:AFIXed:RANGe:UPPer?............................................................................576
:OUTPut<hw>:AMODe................................................................................................... 576
:OUTPut<hw>:IMPedance?.............................................................................................577
:OUTPut<hw>:PROTection:CLEar................................................................................... 577
:OUTPut<hw>:PROTection:TRIPped?..............................................................................577
:OUTPut<hw>[:STATe]...................................................................................................578
:OUTPut<hw>[:STATe]:PON........................................................................................... 578
:OUTPut<hw>:AFIXed:RANGe:LOWer?
Queries the minimum level which can be set when the attenuator is fixed, see :
OUTPut<hw>:AMODe.