Remote Control Commands
R&S
®
SMBV100A
785Operating Manual 1176.8016.02 ─ 17
Parameters:
<Source> INTernal | EXTernal | INT,EXT
INTernal
Uses the internally generated signal for modulation. To configure
the LF signal, use the commands of the SOURce:LFOutput Sub-
system subsystem.
EXTernal
Uses an externally applied modulation signal.
INT,EXT
Uses both, the internal and external modulation signals.
*RST: INT
Example:
PM:SOUR INT
selects the internal modulation source.
Manual operation: See "ɸM Source" on page 257
[:SOURce<hw>]:PM:STATe
<State>
Activates phase modulation.
Note: Activation of PM deactivates frequency modulation (FM).
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
PM:STAT ON
activates PM.
Manual operation: See "State" on page 257
7.16.17 SOURce:POWer Subsystem
This subsystem contains the commands for setting the output level, level control and
level correction of the RF signal.
Other units can also be used instead of dBm:
by entering the unit directly after the numerical value (example :POW 0.5V)
by changing the DEFault unit in the UNIT system (see the command :UNIT:
POWer).
[:SOURce<hw>]:POWer:ALC:OMODe............................................................................. 786
[:SOURce<hw>]:POWer:ALC:SONCe.............................................................................. 786
[:SOURce<hw>]:POWer:ALC[:STATe]............................................................................. 787
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE.........................................................787
[:SOURce<hw>]:POWer:EMF:STATe...............................................................................788
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]..................................................788
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet........................................................788
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL.............................................................789
[:SOURce<hw>]:POWer:LIMit[:AMPLitude].......................................................................789
SOURce Subsystem