Remote Control Commands
R&S
®
SMBV100A
646Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT <Next>
Selects the segment to be output.
Parameters:
<Next> float
Range: 0 to 1023
*RST: 0
Example:
MMEM:CDIR '/var/user/waveform'
sets the default directory.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:TRIG:SMOD NEXT
selects extended trigger mode next, i.e. the segment specified
with command :BB:ARB:WSEG:NEXT will be output.
BB:ARB:SEQ AUTO
selects trigger mode Auto.
BB:ARB:WAV:SEL 'multi_wv1'
loads multi segment waveform multi_wv1.wv. Generation of
segment 2 starts.
BB:ARB:WSEG:NEXT 3
switched at once to output of segment 3.
Manual operation:
See "Next Segment" on page 394
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute
Triggers manually switchover to the subsequent segment in the mutli segment file. A
manual trigger can be executed only when an internal next segment source
(BB:ARB:WSEG:NEXT:SOUR INT) has been selected.
To perform a switchover to any segment within the multi segment file, select the next
segment with the command BB:ARB:WSEG:NEXT.
This command is disabled, if a sequencing play list is enabled.
Example:
BB:ARB:WSEG:NEXT:SOUR INT
selects internal next segment source.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:WSEG:NEXT:EXEC
executes a switchover to the next segment.
Usage: Event
Manual operation: See "Execute Next Segment" on page 400
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce <Source>
Selects the next segment source, i.e. determines whether the next segment is
switched upon receiving of an external trigger signal or upon executing of software trig-
ger .
SOURce Subsystem