Remote Control Commands
R&S
®
SMBV100A
676Operating Manual 1176.8016.02 ─ 17
Return values:
<Free> integer
Range: 0 to INT_MAX
*RST: 0
Example:
BB:DM:FORM USER
selects the User modulation type.
BB:DM:FLIS:FREE?
queries the free memory.
Usage: Query only
[:SOURce<hw>]:BB:DM:CLISt:COPY
<Filename>
[:SOURce<hw>]:BB:DM:DLISt:COPY <Filename>
The command copies the selected data list into the data list specified by <list name>. If
a data list with the specified name already exists, it is overwritten. If it does not yet
exist, it is created.
The source file has to be available in the default directory. The default directory is set
using command MMEM:CDIRectory. A path can be specified, in which case the
source file is copied into the file <list name> in the specified directory. The file exten-
sion may be omitted.
Only files with the file extension *.dm_iqc will be copied (see also Table 7-2).
Setting parameters:
<Filename> string
Example:
BB:DM:DLIS 'd_list1'
selects data list d_list1.
BB:DM:DLIS:COPY 'd_list2'
copies the content of data list d_list1 into data list d_list2.
Any existing content in data list d_list2 is overwritten.
Usage: Setting only
Manual operation: See "File Manager" on page 363
[:SOURce<hw>]:BB:DM:CLISt:TAG?
[:SOURce<hw>]:BB:DM:DLISt:TAG?
The command queries the content of the specified tag in the selected file.
Return values:
<Tag> <control list>,<tag name>
Example:
BB:DM:DLIS:TAG 'D_list1','date'
queries the Date tag in control list D_list1.
Response:10.10.2008
the data list was created on 10.10.2008.
Usage: Query only
SOURce Subsystem