Remote Control Commands
R&S
®
SMBV100A
664Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:FREQuency?
Queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PULSe. The pulse frequency is derived by
dividing the symbol rate by the divider.
Return values:
<Frequency> float
Example:
BB:DM:TRIG:OUTP2:PULS:DIV 2
sets the divider marker signal on output MARKER 2 to the value
2.
BB:DM:TRIG:OUTP2:MODE PULS
enables the pulsed marker signal.
BB:DM:TRIG:OUTP2:PULS:FREQ?
queries the pulse frequency of the marker signal.
Response: 33 000
the resulting pulse frequency is
Usage: Query only
Filter Settings
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling......................................................................664
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling:AUTO............................................................ 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine[:ROLLoff]...........................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:GAUSs..........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs...........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM................................................... 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:PGAuss.........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:RCOSine....................................................... 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:SPHase.........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine:BANDwidth........................................666
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:GAUSs...................................... 666
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:LOWPass.................................. 666
[:SOURce<hw>]:BB:DM:FILTer:TYPE..............................................................................667
[:SOURce<hw>]:DM:FILTer:PARameter...........................................................................667
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling <OSampling>
The command sets the upsampling factor.
Parameters:
<OSampling> integer
Range: 1 to 32
*RST: 32
Example:
BB:DM:FILT:OSAM 32
sets the upsampling factor to 32.
Manual operation: See "Oversampling" on page 361