EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Filter Settings

Rohde & Schwarz SMBV100A
911 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
664Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:PULSe:FREQuency?
Queries the pulse frequency of the pulsed marker signal in the setting
SOURce:BB:DM:TRIGger:OUTPut:MODE PULSe. The pulse frequency is derived by
dividing the symbol rate by the divider.
Return values:
<Frequency> float
Example:
BB:DM:TRIG:OUTP2:PULS:DIV 2
sets the divider marker signal on output MARKER 2 to the value
2.
BB:DM:TRIG:OUTP2:MODE PULS
enables the pulsed marker signal.
BB:DM:TRIG:OUTP2:PULS:FREQ?
queries the pulse frequency of the marker signal.
Response: 33 000
the resulting pulse frequency is
Usage: Query only
Filter Settings
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling......................................................................664
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling:AUTO............................................................ 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine[:ROLLoff]...........................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:GAUSs..........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs...........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM................................................... 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:PGAuss.........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:RCOSine....................................................... 665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:SPHase.........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25........................................................665
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine:BANDwidth........................................666
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:GAUSs...................................... 666
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:LOWPass.................................. 666
[:SOURce<hw>]:BB:DM:FILTer:TYPE..............................................................................667
[:SOURce<hw>]:DM:FILTer:PARameter...........................................................................667
[:SOURce<hw>]:BB:DM:FILTer:OSAMpling <OSampling>
The command sets the upsampling factor.
Parameters:
<OSampling> integer
Range: 1 to 32
*RST: 32
Example:
BB:DM:FILT:OSAM 32
sets the upsampling factor to 32.
Manual operation: See "Oversampling" on page 361