Remote Control Commands
R&S
®
SMBV100A
757Operating Manual 1176.8016.02 ─ 17
Example:
IQ:OUTP:DIG:SRAT:MODE USER
with sample rate source User the internally generated clock ref-
erence signal is selected.
IQ:OUTP:DIG:SRAT 100 MHz
the sample rate for the output signal is set to 100 MHz.
Manual operation: See "Sample Rate Value - Digital I/Q Output" on page 321
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce <Source>
Selects the source for setting the sample rate of the digital I/Q output signal.
Note: With a connected R&S EX-IQ-Box either the internal clock source (User defined)
or an external clock (Digital I/Q In) can be selected in the settings dialog of the R&S
EX-IQ-Box. Therefore, the sample rate source is only indicated in this field.
Parameters:
<Source> USER | DIN | DOUT | USER | DOUT
USER
The internally generated clock reference signal is used. The
sample rate is calculated and displayed in the field "Value".
DOUT
An external clock reference signal is used. The clock signal is
directly fed in via pin CLK2 of the digital output interface (option
R&S SMBV-B18, Digital I/Q Out). The sample rate is displayed
in the field "Value".
*RST: USER
Example:
IQ:OUTP:DIG:SRAT:SOUR USER
the internally generated clock reference signal is selected.
Manual operation: See "Sample Rate Source - Digital I/Q Output" on page 320
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe <State>
Switches on and off the digital I/Q output signals.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
IQ:OUTP:DIG:STAT ON
the digital I/Q output signals of path A are activated.
Manual operation: See "State - Digital I/Q Output" on page 320
7.16.11 SOURce:LFOutput Subsystem
The SOURce:LFOutput subsystem contains the commands for setting the LF signal
source in CW and Sweep mode and for analog modulation.
SOURce Subsystem