Remote Control Commands
R&S
®
SMBV100A
756Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP:MODE <Mode>
Activates (USER) or deactivates (DECimal) the user-defined step width used when
varying the level value with the level values UP/DOWN. The command is linked to set-
ting"Variation Active" for manual operation, i.e. the command also activates/deacti-
vates the user-defined step width used when varying the level value with the rotary
knob.
Parameters:
<Mode> DECimal | USER
*RST: DECimal
Example:
IQ:OUTP:DIG:POW:STEP:MODE USER
actives the step width for level variation with the rotary knob
(manual operation) and with level values UP/DOWN (remote
control).
Manual operation: See "Variation Active - Digital I/Q Out " on page 322
[:SOURce<hw>]:IQ:OUTPut:POWer:VIA
<Via>
Activates the selected I/Q output level entry fields of the currently selected signal path
in the status bar.
Parameters:
<Via> PEP | LEVel
PEP
The signal level is expressed in terms of a peak envelope power
value (PEP). The level entry fields and the corresponding units
are displayed in the status bar.
LEVel
The signal level is expressed in terms of a rms value. The level
entry field and the corresponding units are displayed in the sta-
tus bar.
*RST: PEP
Example:
IQ:OUTP:POW:VIA PEP
the I/Q-signal level is set via PEP for the signal of path A.
Manual operation: See "Set Level Via" on page 321
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe <SRate>
Using the sample rate source User, the command sets the sample rate value of the
output signal. This command is not active for external clock sources
Parameters:
<SRate> float
Range: 400 to max
Increment: 0.001
*RST: 1E8
SOURce Subsystem