Remote Control Commands
R&S
®
SMBV100A
600Operating Manual 1176.8016.02 ─ 17
SOURce:BB Subsystem General Commands...................................................... 600
SOURce:BB:ARB Subsystem...............................................................................601
SOURce:BB:DM Subsystem.................................................................................648
SOURce:BB:GRAPhics Subsystem......................................................................686
SOURce:BB:IMPairment Subsystem....................................................................689
SOURce:BB:MCCW Subsystem...........................................................................692
SOURce:BB:PROGress Subsystem General Commands....................................715
7.16.3.1 SOURce:BB Subsystem General Commands
The following section describes the commands for setting the frequency shift and the
phase offset for the signal at the "Baseband" block output.
[:SOURce<hw>]:BB:FOFFset..........................................................................................600
[:SOURce<hw>]:BB:POFFset..........................................................................................600
[:SOURce<hw>]:BB:FOFFset <FOffset>
Sets the frequency offset for the baseband signal. The offset affects the signal on the
baseband block output. It shifts the useful baseband signal in the center frequency.
Parameters:
<FOffset> float
Increment: 0.01
*RST: 0
Example:
BB:FOFF 2MHZ
sets a frequency offset of 2 MHz.
Manual operation: See "Frequency Offset" on page 324
[:SOURce<hw>]:BB:POFFset <POffset>
The command sets the relative phase offset of the baseband signal.
The phase offset affects the signal on the "baseband block" output.
Parameters:
<POffset> float
Range: 0 to 359.9
Increment: 0.01
*RST: 0
Default unit: DEG
Example:
BB:POFF 0.5DEG
sets a relative phase offset of 0.5 DEG for the baseband signal
Manual operation: See "Phase Offset" on page 326