Remote Control Commands
R&S
®
SMBV100A
753Operating Manual 1176.8016.02 ─ 17
7.16.10.2 Digital I/Q Outputs
This subsystem contains the commands for configuring the digital I/Q output. The digi-
tal signal can be output with the aid of a standardized (LVDS) digital user interface.
For information about the required options, see Chapter 5.8, "Digital I/Q Output Set-
tings", on page 320.
[:SOURce<hw>]:IQ:OUTPut:DIGital:CDEVice?................................................................. 753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet..........................................................753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:STATe?....................................................... 753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:STATe?.................................................................754
[:SOURce<hw>]:IQ:OUTPut:DIGital:PON......................................................................... 754
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:LEVel............................................................ 754
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:PEP.............................................................. 755
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP[:INCRement].........................................755
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP:MODE..................................................756
[:SOURce<hw>]:IQ:OUTPut:POWer:VIA.......................................................................... 756
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe......................................................................756
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce........................................................ 757
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe...................................................................... 757
[:SOURce<hw>]:IQ:OUTPut:DIGital:CDEVice?
Queries the ID of a connected Rohde&Schwarz instrument.
Return values:
<CDevice> string
Example:
IQ:OUTP:DIG:CDEV?
queries the connected device ID.
Usage: Query only
Manual operation: See "Connected Device - Digital I/Q Out" on page 323
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet
Resets the overflow hold state and LED.
Example:
SOUR:IQ:OUTP:DIG:OFL:HOLD:RESet
resets the overflow hold state.
Usage: Event
Manual operation: See "Reset - Digital I/Q Out" on page 323
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:STATe?
Queries an overflow since the last reset.
To reset the overflow hold state, use one of the following:
send the command [:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet