Remote Control Commands
R&S
®
SMBV100A
599Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?
In Additive Noise and CW Interferer (SOUR:AWGN:MODE ADD|CW) modes, queries the
peak envelope power of the overall signal comprised of noise signal plus useful signal.
Return values:
<Pep> float
Range: -145 to 20
Increment: 0.01
*RST: 0
Example:
SOURce:AWGN:POWer:SUM:PEP?
queries the peak envelope power of the overall signal.
Usage: Query only
Manual operation: See " Carrier + Noise PEP / Signal + Noise PEP (Total Band-
width) / Carrier + Interferer PEP / Signal + Interferer PEP "
on page 315
[:SOURce<hw>]:AWGN:STATe
<State>
Activates or deactivates the white noise (AWGN = Averaged White Gaussian Noise).
Use the command [:SOURce<hw>]:AWGN:MODE to define the mode the AWGN gen-
erator is working in.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
SOURce:AWGN:STATe ON
Manual operation: See " State - AWGN " on page 309
7.16.3 SOURce:BB Subsystem
This subsystem contains all commands for digital signal generation. It is divided into
several subsystems which are described separately.
OUTPut<ch>
The numeric suffix to OUTPut distinguishes between the available markers.
Only two markers are available for the R&S SMBV, i.e. the allowed values for the suffix
are 1 or 2.
EXTernal<ch>
The numeric suffix to EXTernal distinguishes between the available external trigger
inputs.