EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Page 610

Rohde & Schwarz SMBV100A
911 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
595Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:AWGN:FREQuency:RESult?
In CW inerferer mode, queries the actual frequency of the sine.
The actual frequency may differ from the desired frequency, since the resolution is limi-
ted to 0.7 Hz.
Return values:
<Result> float
Range: -40E6 to 40E6
Increment: 0.01
*RST: 0
Example:
AWGN:FREQ:RES?
queries the actual frequency of the interfering sine
Usage: Query only
Manual operation: See " Resulting CW Frequency - AWGN " on page 311
[:SOURce<hw>]:AWGN:FREQuency:TARGet <Target>
Sets the desired frequency of the sine in AWGN:MODE CW mode.
The resulting frequency may differ from the desired frequency because of the limited
frequency resolution of 0.7 Hz.
Parameters:
<Target> float
Range: -40E6 to 40E6
Increment: 0.01
*RST: 0
Example:
AWGN:FREQ:TARG 2kHz
sets a frequency of 2 kHz for the interfering sine.
Manual operation: See " Target CW Frequency - AWGN " on page 311
[:SOURce<hw>]:AWGN:MODE <Mode>
Selects the mode for generating the interfering signal.
Parameters:
<Mode> ONLY | ADD | CW
ADD
The AWGN noise signal is added to the baseband signal.
ONLY
The pure AWGN noise signal is modulated to the carrier. The
connection to the baseband is interrupted.
CW
The sine interfering signal is added to the baseband signal.
*RST: ADD