Remote Control Commands
R&S
®
SMBV100A
652Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:DM:SWITching:STATe <State>
Enables switching between a modulated and an unmodulated signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
BB:DM:SWIT:STAT INT
CW switching is active.
Manual operation: See "State Mod - CW" on page 359
Clock Settings
[:SOURce<hw>]:BB:DM:CLOCk:MODE............................................................................652
[:SOURce<hw>]:BB:DM:CLOCk:MULTiplier......................................................................652
[:SOURce<hw>]:BB:DM:CLOCk:SOURce........................................................................ 653
[:SOURce<hw>]:BB:DM:CLOCk:SYNChronization:MODE..................................................653
[:SOURce<hw>]:BB:DM:CLOCk:SYNChronization:EXECute.............................................. 654
[:SOURce<hw>]:BB:DM:CLOCk:MODE <Mode>
The command enters the type of externally supplied clock (:BB:DM:CLOCk:SOURce
EXTernal).
Parameters:
<Mode> SYMBol | MSYMbol
*RST: SYMBol
Example:
BB:DM:CLOC:MODE SYMB
selects clock type Symbols, i.e. the supplied clock is a symbol
clock.
Manual operation: See "Clock Mode" on page 378
[:SOURce<hw>]:BB:DM:CLOCk:MULTiplier <Multiplier>
The command specifies the multiplier for clock type Multiple Symbols (BB:DM:CLOCk:
MODE MSYM) in the case of an external clock source.
Parameters:
<Multiplier> integer
Range: 1 to 64
*RST: 4
SOURce Subsystem