Remote Control Commands
R&S
®
SMBV100A
688Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:BB:GRAPhics:SRATe:USER <User>
(Enabled for BB:GRAPH:SRAT:MODE USER)
Selects the signal bandwidth for which the display is to be generated. The setting
range moves between the minimum and maximum bandwidth which is possible for the
selected display. The selection is made graphically by moving the pointer.
Parameters:
<User> float
Range: 0.01 to 100
Increment: 0.01
*RST: 10
Default unit: PCT
Example:
BB:GRAP:SRAT:MODE USER
sets the sample rate mode.
BB:GRAP:SRAT:USER 20
sets the sample rate factor.
Manual operation: See "Graphics Sample Rate" on page 176
[:SOURce<hw>]:BB:GRAPhics:STATe <State>
Activates/deactivates the selected graphical display.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
BB:GRAP:STAT ON
activates the graphical graphics.
Manual operation: See "State" on page 175
[:SOURce<hw>]:BB:GRAPhics:TRIGger:SOURce <Source>
Defines the trigger for the starting time of the graphic recording.