Remote Control Commands
R&S
®
SMBV100A
705Operating Manual 1176.8016.02 ─ 17
Parameters:
<Delay> float
Range: 0 to 65535
Increment: 0.01
*RST: 0
Example:
BB:MCCW:TRIG:SOUR EXT
selects an external trigger
BB:MCCW:TRIG:DEL 200
sets a delay of 200 samples for the trigger.
[:SOURce<hw>]:BB:MCCW:TRIGger:OBASeband:INHibit <Inhibit>
Sets the number of samples by which a restart is to be inhibited following a trigger
event. This command applies only in the case of external triggering.
Parameters:
<Inhibit> integer
Range: 0 to 67108863
*RST: 0
Example:
BB:MCCW:TRIG:SOUR EXT
selects an external trigger
BB:MCCW:TRIG:INH 200
sets a restart inhibit for 200 samples following a trigger event.
[:SOURce<hw>]:BB:MCCW:TRIGger:RMODe?
Queries the current status of signal generation for all trigger modes with Multi Carrier
CW on.
Return values:
<RMode> STOP | RUN
RUN
The signal is generated. A trigger event occurred in the triggered
mode.
STOP
The signal is not generated. A trigger event did not occur in the
triggered modes, or signal generation was stopped by the com-
mand BB:MCCW:TRIG:ARM:EXECute (armed trigger modes
only).
Example:
SOURBB:MCCW:TRIG:SOUR EXT
sets external triggering
SOURBB:MCCW:TRIG:MODE ARET
selects the Armed_Retrigger mode
SOURBB:MCCW:TRIG:RMOD?
queries the current status of signal generation.
Response: RUN
the signal is generated, an external trigger was executed.
SOURce Subsystem