Remote Control Commands
R&S
®
SMBV100A
792Operating Manual 1176.8016.02 ─ 17
[:SOURce<hw>]:POWer:PEP?
Queries the peak envelope power (PEP) in dBm for digital modulation and all digital
standards This value corresponds to the value shown under the Level specification in
the PEP lines in the display header.
Return values:
<Pep> float
Example:
POW:PEP?
queries the PEP value for RF output A in the case of digital mod-
ulation.
Response: 4
the PEP value for RF output A is 4 dBm.
Usage: Query only
[:SOURce<hw>]:POWer:POWer <Power>
Sets the RF level of the RF output connector.
The level entered with this command corresponds to the level at the RF output, i.e. any
offset entry is not taken into consideration.
Note: The SCPI command [:SOURce<hw>]:POWer[:LEVel][:IMMediate][:
AMPLitude] sets the level of the "Level" display, i.e. the level containing offset.
Parameters:
<Power> Minimum level ... Maximum level
The value range for the level setting varies according to the
instrument model.
The values are given in the data sheet.
Increment: 0.01
*RST: -30
Example:
SOUR:POW:POW 15
sets the RF level at output to 15 dBm.
Manual operation: See "Amplitude" on page 222
[:SOURce<hw>]:POWer:SPC:CRANge <PowCntrlCRange>
Defines the capture range of the power control system.
Within the range:
Target Level +/- Catch Range
the power control locks and tries to achieve the target level. Readings outside the
range are not considered.