Remote Control Commands
R&S
®
SMBV100A
815Operating Manual 1176.8016.02 ─ 17
Parameters:
<Points> integer
Range: 2...max
Example:
POW:STAR - 30 dBm
sets the start frequency to -30 dBm.
POW:STOP - 10 dBm
sets the stop frequency to -10 dBm.
SWE:POW:POIN 20
sets 20 sweep steps. The sweep step width (STEP) is automati-
cally set to 1 dB.
[:SOURce<hw>]:SWEep:POWer:RETRace <State>
Activates that the signal changes to the start level value while it is waiting for the next
trigger event.
You can enable this feature, when you are working with sawtooth shapes in sweep
mode "Single" or "External Single".
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
TRIG0:SWE:SOUR SING
POW:MODE SWE
SWE:POW:SHAP SAWT
SWE:POW:RETR ON
activates retrace function, i.e. the level changes to the value at
start level while waiting for the next trigger event.
Manual operation: See " Retrace - RF Level Sweep " on page 287
[:SOURce<hw>]:SWEep:POWer:RUNNing?
Queries the current state of the level sweep mode.
Return values:
<State> 0 | 1 | OFF | ON
Example:
SWE:POW:RUNN?
Response "1": signal generation in level sweep active.