4. Click Submit, or cancel by clicking the X-icon in the top-right corner.
Accessing the SNMP Support MIB Files
Safran Trusted 4D (formerly Orolia/Spectracom)’s private enterprise MIB files
can be extracted via File Transfer Protocol (FTP) from VersaSync, using an FTP
client such as FileZilla or any other shareware/freeware FTP program.
Note: Current VersaSync Time and Frequency Synchronization Sys-
tem software requires SFTP to ensure increased security.
To obtain the MIB files from VersaSync via FTP/SFTP:
1. Using an FTP program, log in as an administrator.
2. Through the FTP program, locate Safran Trusted 4D's Spectracom MIB files
in the /home/spectracom/mibs directory.
3. FTP the files to the desired location on your PC for later transfer to the
SNMP Manager.
4. Compile the MIB files onto the SNMP Manager.
Note: When compiling the MIB files, some SNMP Manager pro-
grams may require the MIB files to be named something other
than the current names for the files. The MIB file names may be
changed or edited as necessary to meet the requirements of
the SNMP Manager. Refer to the SNMP Manager doc-
umentation for more information on these requirements.
Note: In addition to the Orolia/Spectracom MIB files, there are
also some net-snmp MIB files provided. Net-snmp is the
embedded SNMP agent that is used in the VersaSync and it
provides traps to notify the user when it starts, restarts, or
shuts down. These MIB files may also be compiled into your
SNMP manager, if they are not already present.
Safran Trusted 4D’s private enterprise MIB files can be requested and
obtained from the Safran Customer Service department via email at
TimingSupport@nav-timing.SafranGroup.com.