Reference—Indicates the status of the current synchronizing reference, if
any.
Power—Indicates whether the power is on.
Status—Indicates the status of the network’s timing. There are three indic-
ators in the Status field:
Sync—Indicates whether VersaSync is synchronized to its selected
input references.
Green indicates VersaSync is currently synchronized to its ref-
erences.
Orange indicates VersaSync is not currently synchronized to its
references.
Hold—When lit, VersaSync is in Holdover mode.
Fault—Indicates a fault in the operation of the VersaSync. See
"Troubleshooting via Web UI Status Page" on page306 for instruc-
tions for troubleshooting faults.
Alarm Status: If a major or minor alarm is present, it will be displayed here.
NTP—Current STRATUM status of this VersaSync unit.
Temperature—The current board temperature will be displayed here.
Reference Status panel
REFERENCE: Indicates the name type of each reference. These are determ-
ined by the inputs set up for the VersaSync
PRIORITY: Indicates the priority of each reference. This number will be
between 1 and 15. References in this panel appear in their order of priority.
See "Configuring Input Reference Priorities" on page173 for more inform-
ation.
STATUS: Indicates which available input reference is acting as the Time ref-
erence and which available input reference is acting as the 1PPS reference.
Green indicates that the reference is present and has been declared
valid.
Orange indicates the input reference is not currently present or is not
currently valid.
Performance panel
Disciplining State—Indicates whether or not the internal oscillator is cur-
rently being disciplined (steered to an input reference).