IRIG A: 10 KHz
IRIG B: 1 KHz
IRIG G: 100 KHz
NASA 36: 1 KHz
IRIG E: 1 KHz
Amplitude: Must be between 0 and 255.
Coded Expression: [(0) BCD TOY, CF, BS, (1) BCD TOY, CF, (2) BCD TOY, (3)
BCD TOY, BS, (4) BCD TOY/Year, CF, BS, (5) BCD TOY/Year, CF, (6) BCD
TOY/Year, (7) BCD TOY/Year, BS], where:
BCD = Binary Coded Decimal
TOY = Time of Year
CF = Control Function
BS = Binary Seconds
Note: the available Coded Expressions options will change based on your pre-
vious selections.
Control Function Conformance: [Fields conform to RCC 200-04, IEEE C37.118-
2005, Spectracom format, Spectracom FAA format, or Spectracom IEEE
C37.188-2005]
Offset: Account for cable delays or other latencies. The value is entered and dis-
played in nanoseconds; the available range is -500 to +500 ms.
IRIGAMInput settings
Format: [(A) IRIG A, (B) IRIG B, (G) IRIG G, (N) NASA 36, (E) IRIG E]
Modulation: [(0) IRIG DCLS Only, (1) IRIG AM Only] Please note: the IRIG DCLS
only option is non- functional and should not be selected.
Frequency: [(0) No Carrier, (1) 100 Hz, (2) 1 KHz, (3) 10 KHz, (4) 100 KHz, (5) 1
MHz] See previous Note on Format and Frequency
Coded Expression: [(0) BCD TOY, CF, BS, (1) BCD TOY, CF, (2) BCD TOY, (3)
BCD TOY, BS, (4) BCD TOY/Year, CF, BS, (5) BCD TOY/Year, CF, (6) BCD
TOY/Year, (7) BCD TOY/Year, BS], where:
BCD = Binary Coded Decimal
TOY = Time of Year
VersaSync User Manual 389