No Code Alarm Name Definition
26 MJB01 HDLC Comm Error Communications to LCP lost or faulty.
27 MJB02 Memory Alarm 1 A RAM diagnostic check error has occurred in the MP
card.
31 MJB06 IPC MSGQ Over IPC TX queue full error has occurred in the MP card.
Alarm data = IPC Queue type
32 MJB07 IPC MSGQ Under IPC TX queue full recovery has occurred in the MCP2.
Alarm data=IPC Queue type
- MJC-- DSP Error System Resource Fault
35 MJC01 DTMF Fault An abnormal interrupt has occurred in the system
DTMF resources.
Alarm data=DTMF Receiver DSP position
36 MJC02 Tone Fault An abnormal interrupt has occurred in the system
tone resources.
Alarm data=TONE Receiver DSP position.
37 MJC03 CID DSP Fault CID DSP Fault
40 MJC06 AC Pwr Loss AC Power Loss
41 MJC07 AC Pwr Recovery AC Power Recovery
42 MJC08 Low Battery Low Battery
43 MJC09 Low Battery Rec Low Battery Recovery
MJC18 D-BD Init Fault D-board Initial Fault
MJC19 D-BD Init Rec D-board Initial Recovery
MJC20 Card Init Fault Card Initial Fault
MJC21 Card Init Rec Card Initial Recovery
- MJD-- DTRK Error ISDN or E1 card Fault
52 MJD01 Sync Failure Clocking on TEPRI cards has become asynchronous.
53 MJD02 Sync Recovery Clocking on TEPRI cards has become synchronous.
54 MJD03 Red Alarm Locally detected loss of PCM carrier on TEPRI card for
more than 250 ms.
Alarm Data=Cabinet, Slot (Cx-Syy)
55 MJD04 Red Alarm Rec PCM carrier detected locally on TEPRI cards.
Alarm Data=Cabinet, Slot (Cx-Syy)
56 MJD05 Yellow Alarm Remotely detected failure transmitted in frame on
TEPRI card.
Alarm Data=Cabinet, Slot (Cx-Syy)
57 MJD06 Yellow Alarm Rec Remotely detected failure restored transmitted on
TEPRI card.
Alarm Data=Cabinet, Slot (Cx-Syy)
58 MJD07 Blue Alarm All 1s being transmitted on facility on TEPRI card.
Alarm Data=Cabinet, Slot (Cx-Syy)