CHAPTER 2. MMC Programming
2-416
© SAMSUNG Electronics Co., Ltd.
(Continued)
No Code Alarm Name Definition
59 MJD08 Blue Alarm Rec A blue alarm condition has been cleared.
Alarm Data=Cabinet, Slot (Cx-Syy)
60 MJD09 Bit Error Alarm Alarm is activated when the error rate exceeds 1 x 10
-6
errors. Note: 1x10
-6
is threshold for minor alarm, 1 x 10
-3
is
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data=Cabinet, Slot (Cx-Syy)
62 MJD11 SPID Init Error The BRI received an error from the network.
Alarm Data=Cabinet, Slot, Channel (Cx-Syy-czz)
63 MJD12 SPID Init Rec The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
64 MJD13 LPBK Error Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
65 MJD14 LPBK Recovery Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
66 MJD15 BRI DL Unavail A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
67 MJD16 BRI DL Recovery A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
- MJD-- DTRK Error ISDN or E1 card Fault
69 MJD18 E1 Restart The E1 card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
70 MJD19 PRI Restart The PRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
71 MJD20 BRI Restart The BRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
72 MJD21 PCM Loss Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
73 MJD22 PCM Recovery Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
74 MJD23 L2 Disconnect PRI L2 sync alarm
75 MJD24 L2 Connect PRI L2 sync alarm
- MJE-- MGI Error MGI card Fault
76 MJE01 MGI Restart The MGI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
78 MJE03 MGI IP Duplicate The MGI card IP address is duplicated.
Alarm Data = Cabinet, Slot (Cx-Syy)
79 MJE04 MGI NTWK Error The MGI card has blocked because the system detects
the card doesn’t respond via network link.
External ping test.