EasyManua.ls Logo

Samsung OfficeServ 7000 Series - Page 454

Samsung OfficeServ 7000 Series
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2. MMC Programming
2-416
© SAMSUNG Electronics Co., Ltd.
(Continued)
No Code Alarm Name Definition
59 MJD08 Blue Alarm Rec A blue alarm condition has been cleared.
Alarm Data=Cabinet, Slot (Cx-Syy)
60 MJD09 Bit Error Alarm Alarm is activated when the error rate exceeds 1 x 10
-6
errors. Note: 1x10
-6
is threshold for minor alarm, 1 x 10
-3
is
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data=Cabinet, Slot (Cx-Syy)
62 MJD11 SPID Init Error The BRI received an error from the network.
Alarm Data=Cabinet, Slot, Channel (Cx-Syy-czz)
63 MJD12 SPID Init Rec The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
64 MJD13 LPBK Error Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
65 MJD14 LPBK Recovery Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
66 MJD15 BRI DL Unavail A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
67 MJD16 BRI DL Recovery A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
- MJD-- DTRK Error ISDN or E1 card Fault
69 MJD18 E1 Restart The E1 card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
70 MJD19 PRI Restart The PRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
71 MJD20 BRI Restart The BRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
72 MJD21 PCM Loss Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
73 MJD22 PCM Recovery Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
74 MJD23 L2 Disconnect PRI L2 sync alarm
75 MJD24 L2 Connect PRI L2 sync alarm
- MJE-- MGI Error MGI card Fault
76 MJE01 MGI Restart The MGI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
78 MJE03 MGI IP Duplicate The MGI card IP address is duplicated.
Alarm Data = Cabinet, Slot (Cx-Syy)
79 MJE04 MGI NTWK Error The MGI card has blocked because the system detects
the card doesnt respond via network link.
External ping test.
Alarm Data = Cabinet, Slot (Cx-Syy)