[Network]
352
[Additional Port No.]
Register the UDP destination port number to allow communication.
The acceptable input values are as follows:
Active port number An integer from 1 to 65535
Specifying multiple values Delimit active port numbers using a comma “,”
Specifying a range Create a range of active port numbers using a colon “:” (Input in the
order of low port number: high port number)
Maximum number of
specifications
21 ports in total by specifying with either numbers or a range
No setting Blank
Input Example
Port number Comments
10000 -
10000,10001,10002,10003
10000:10003
This results in the same ports in both settings to
be allowed.
10000,10001,10002,10003,20000
10000:10003,20000
This results in the same ports in both settings to
be allowed.
Blank Keep it blank when no setting is needed