EasyManua.ls Logo

ABB IRC5 - Installation of Internal Harness (Euromap 67) in the Dual Cabinet Controller

ABB IRC5
549 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Installation and Commissioning, IRC5
2.9.7. Installation of Euromap and SPI
3HAC021313-001 Revision: K128
© Copyright 2004-2008 ABB. All rights reserved.
Installation of internal harness (Euromap 67) in the Dual Cabinet Controller
The following procedure details how to install the internal harness (Euromap 67) in the Dual
Cabinet Controller.
Action Note/Illustration
1.
DANGER!
Before any work inside the cabinet, please
observe the safety information in section
DANGER - Make sure that the main power has
been switched off! on page 28.
2.
esd
WARNING!
The unit is sensitive to ESD, before handling the
unit please observe the safety information in
section WARNING - The unit is sensitive to
ESD! on page 29
3. Remove the original adapter plate on the front of
the controller.
xx0600002652
A: original adapter plate
B: attachment screw (8 pcs)
4. Fit the included adapter plate.
xx0600002651
A: Euromap adapter plate
B: attachment screw (8 pcs)
A
B
Continued
Continues on next page