If ExpertExpert is selected on "Control" screen, following screen appears.
BDP (Bytes)BDP (Bytes)
Appears when Test mode is set to Auto. If CIR and Baseline RTT are set on
"Control" screen, calculated BDP (Bandwidth-Delay Product) appears.
Desired Max Window SizeDesired Max Window Size
Appears when Test mode is set to Auto. The nominal window size to be used if
possible. If specified window size is lower than BDP/16, a larger window size
will be calculated and used automatically.
Window ScanWindow Scan
Touch the Step DurationStep Duration field to set the duration of each steps.
Select the check boxes to execute the step in the table.
Auto
Test parameters are set automatically.
Expert
Window SizeWindow Size: Touch the field to set TCP window size.
ConnectionsConnections: Touch the field to set TCP connection number.
TotalTotal: Calculated bytes are displayed.