EasyManuals Logo

Applied Biosystems 7900HT User Manual

Applied Biosystems 7900HT
384 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
DRAFT
September 1, 2004 11:38 am, CH_Overview.fm
Compatible Consumables
Applied Biosystems 7900HT Fast Real-Time PCR System and SDS Enterprise Database User Guide 1-9
Compatible Consumables
Consumables for
Use with the
7900HT
Instrument
The interchangeable sample block modules of the 7900HT instrument allow it to
support a variety of consumable formats listed in Table 1-1.
Compression
Pads for the
ABI PRISM
96-Well Optical
Reaction Plates
To ensure optimal heat transfer, Applied Biosystems recommends using compression
pads when running the ABI P
RISM 96-Well Optical Reaction Plates.
If you are going to run the plate:
Individually using the SDS software, then apply a standard compression pad
As part of a batch using the Automation Controller Software, then apply an
ABI P
RISM Snap-On Compression Pad
IMPORTANT! The ABI PRISM
Snap-On Compression Pad/plate assembly may still
be hot after the Zymark
®
Twister Microplate Handler loads it into the Plate Handler’s
output stack. Please wait at least 30 seconds before manually handling the Snap-On
Compression Pad/plate assembly.
IMPORTANT! Performance of the Optical 96-Well Fast Thermal Cycling Plates with
the Zymark Twister Microplate Handler has not been verified. Therefore, when
running multiple Optical 96-Well Fast Plates on the 7900HT instrument, Applied
Biosystems recommends that you load and unload the plates manually.
Consumable
Requirements
See Appendix C, “Kits, Reagents, and Consumables, for a list of available
consumables, requirements, and purchasing instructions.
Table 1-1 Compatible Consumables
Consumable Compatible Seals
ABI P
RISM
384-Well Optical
Reaction Plates
•ABIPRISM
Optical Adhesive Covers
(quantity 100)
Optical Adhesive Covers (quantity 25)
ABI P
RISM
96-Well Optical
Reaction Plates
Compression Pads:
Standard pad for manual operation
–ABIP
RISM
Snap-On Compression Pad
(reusable)
96-Well Plate Seals:
–ABIP
RISM
Optical Adhesive Covers
(quantity 100)
Optical Adhesive Covers (quantity 25)
–ABIP
RISM
Optical Caps (flat caps only)
Optical 96-Well Fast Thermal
Cycling Plates
•ABIP
RISM
Optical Adhesive Covers
(quantity 100)
Optical Adhesive Covers (quantity 25)
Taq Ma n
®
Low Density Arrays None (self sealing)

Table of Contents

Other manuals for Applied Biosystems 7900HT