303
Questions Solutions
NVR cannot control PTZ.
Front panel PTZ error
PTZ decoder setup, connection or installation is not
correct.
Cable connection is not correct.
PTZ setup is not correct.
PTZ decoder and NVR protocol is not compatible.
PTZ decoder and NVR address is not compatible.
When there are several decoders, add 120 Ohm
between the PTZ decoder A/B cables furthest end to
delete the reverberation or impedance matching.
Otherwise the PTZ control is not stable.
The distance is too far.
I cannot log in client-end or
web.
For Windows 98 or Windows ME user, update your
system to Windows 2000 sp4. Or you can install
client-end software of lower version. Please note right
now, our NVR is not compatible with Windows VISTA
control.
ActiveX control has been disabled.
No dx8.1 or higher. Upgrade display card driver.
Network connection error.
Network setup error.
Password or user name is invalid.
Client-end is not compatible with NVR program.
There is only mosaic no
video when preview or
playback video file remotely.
Network fluency is not good.
Client-end resources are limit.
Current user has no right to monitor.
Network connection is not
stable.
Network is not stable.
IP address conflict.
MAC address conflict.
PC or device network card is not good.
Burn error /USB back error.
Burner and NVR are in the same data cable.
System uses too much CPU resources. Stop record first
and then begin backup.
Data amount exceeds backup device capacity. It may
result in burner error.
Backup device is not compatible.
Backup device is damaged.
Keyboard cannot control
NVR.
NVR serial port setup is not correct.
Address is not correct.
When there are several switchers, power supply is not
enough.
Transmission distance is too far.
Copyright © NSS Sp. z o.o.