Battery charging system
file:///D|/Manuales/Para%20recolocar/MOTOS/DUCATI/DUCATI/M796/wsm/EN/M796_ABS_11_6_2.26.1.html[11/12/2015 18:40:20]
Important
Never move the container away from the battery. Do not cut or puncture the liquid container.
Make sure that all the electrolyte has flowed out. Carefully extract the container (2) from the battery.
Place the sealing cap strip (3) previously removed from the electrolyte container (2) on the battery, taking care not to
force it into the filler holes.
For 3-12 Ah batteries, leave to stand for at least 30 min.
For batteries of over 12 Ah, leave to stand for at least 1 hour.
Note
If using an automatic charge reducing battery charger, make certain that the charger current (amps) is greater than or
equal to the standard (STD) recharging system indicated on the battery.
Press down firmly with both hands until the caps are firmly in place (do not use a hammer).